Epever Tracer MPPT controller
Manufacturer: EP Solar Technology Co.Ltd.
Product: EPEVER Tracer
Model: Tracer-AN
Class: MODBUS
Updated: 2023-11-13
[ CLICK HERE FOR MORE INFORMATION ]
Registers
# | Name | Unit | Description |
---|---|---|---|
1 | PV array rated voltage | V | |
2 | PV array rated current | A | |
3 | PV array rated power | W | |
4 | Battery rated voltage | V | |
5 | Battery rated charge current | A | |
6 | Battery rated charge power | W | |
7 | Output rated current | A | |
8 | PV array voltage | V | |
9 | PV array current | A | |
10 | PV array power | W | |
11 | Battery voltage | V | |
12 | Battery current | A | |
13 | Battery power | W | |
14 | Load voltage | V | |
15 | Load current | A | |
16 | Load power | W | |
17 | Battery temperature | °C | |
18 | Case internal temperature | °C | |
19 | Heatsink temperature | °C | |
20 | Battery State Of Charge | % | |
21 | Remote battery temperature | °C | |
22 | Battery rated voltage | V | |
23 | Battery status (V) | ||
24 | Battery status (T) | ||
25 | Battery status | ||
26 | Input volt status | ||
27 | Charging status | ||
28 | Equipment status | ||
29 | PV max volt today | V | |
30 | PV min volt today | V | |
31 | Battery max volt today | V | |
32 | Battery min volt today | V | |
33 | Energy used today | kWh | |
34 | Energy used this month | kWh | |
35 | Energy used this year | kWh | |
36 | Energy used total | kWh | |
37 | Energy generated today | kWh | |
38 | Energy generated this month | kWh | |
39 | Energy generated this year | kWh | |
40 | Energy generated total | kWh | |
41 | CO2 reduction | ton | |
42 | Battery net current | A | |
43 | Battery temperature | °C | |
44 | Ambient temperature | °C |
Notes
MPPT Solar Charge Controller Modbus/RTU connections: PINOUT using EIA586B cable is 1: n/c 2: n/c 3: RS485 A Green/White 4: RS485 A Blue 5: RS485 B Blue/White 6: RS485 B Green 7: GND Brown/White 8: GND Brown EPEVER RS485 B = ezeio D0 EPEVER RS485 A = ezeio D1 EPEVER GND = ezeio 0V Default is 115200/N81, address 1