CCS WattNode (advanced) [OBSOLETE]

Manufacturer: CCS Continental Control Systems
Product: WattNode
Model: WND-M1-MB
Class: MODBUS
Updated: 2023-11-13
[ CLICK HERE FOR MORE INFORMATION ]
Registers
| # | Name | Unit | Description |
|---|---|---|---|
| 1 | Total Net Energy | kW h | Bidirectional, Active, Resettable |
| 2 | Total Positive Energy | kW h | Positive, Active, Resettable |
| 3 | Total Negative Energy | kW h | Negative, Active, Resettable |
| 4 | Total Power | kW | Total, Active |
| 5 | Avg Volt L-N | V | Line-to-Neutral |
| 6 | Avg Volt L-L | V | Line-to-Line |
| 7 | Frequency | Hz | |
| 8 | Avg Power Factor | Average | |
| 9 | Current ph A | A | Phase A |
| 10 | Current ph B | A | Phase B |
| 11 | Current ph C | A | Phase C |
| 12 | Total Net Energy NR | kW h | Bidirectional, Active, Not resettable |
| 13 | Energy ph A | kW h | Bidirectional, Active, Phase A |
| 14 | Energy ph B | kW h | Bidirectional, Active, Phase B |
| 15 | Energy ph C | kW h | Bidirectional, Active, Phase C |
| 16 | Power ph A | kW | Active, Phase A |
| 17 | Power ph B | kW | Active, Phase B |
| 18 | Power ph C | kW | Active, Phase C |
| 19 | Volt A-N | V | RMS |
| 20 | Volt B-N | V | RMS |
| 21 | Volt C-N | V | RMS |
| 22 | Volt A-B | V | RMS |
| 23 | Volt B-C | V | RMS |
| 24 | Volt C-A | V | RMS |
| 25 | Power Factor ph A | ||
| 26 | Power Factor ph B | ||
| 27 | Power Factor ph C | ||
| 28 | Positive Energy ph A | kW h | Active, Phase A |
| 29 | Positive Energy ph B | kW h | Active, Phase B |
| 30 | Positive Energy ph C | kW h | Active, Phase C |
| 31 | Negative Energy ph A | kW h | Active, Phase A |
| 32 | Negative Energy ph B | kW h | Active, Phase B |
| 33 | Negative Energy ph C | kW h | Active, Phase C |
| 34 | Total Reactive Energy | kVAR h | Bidirectional, Reactive |
| 35 | Reactive Energy ph A | kVAR h | Bidirectional, Reactive, Phase A |
| 36 | Reactive Energy ph B | kVAR h | Bidirectional, Reactive, Phase B |
| 37 | Reactive Energy ph C | kVAR h | Bidirectional, Reactive, Phase C |
| 38 | Total Apparent Energy | kVA h | Bidirectional, Reactive |
| 39 | Apparent Energy ph A | kVA h | Bidirectional, Apparent, Phase A |
| 40 | Apparent Energy ph B | kVA h | Bidirectional, Apparent, Phase B |
| 41 | Apparent Energy ph C | kVA h | Bidirectional, Apparent, Phase C |
| 42 | Total Reactive Power | kVAR | Bidirectional |
| 43 | Reactive Power ph A | kVAR | Bidirectional, Phase A |
| 44 | Reactive Power ph B | kVAR | Bidirectional, Phase B |
| 45 | Reactive Power ph C | kVAR | Bidirectional, Phase C |
| 46 | Total Apparent Power | kVAR | Bidirectional |
| 47 | Apparent Power ph A | kVAR | Bidirectional, Phase A |
| 48 | Apparent Power ph B | kVAR | Bidirectional, Phase B |
| 49 | Apparent Power ph C | kVAR | Bidirectional, Phase C |
| 50 | Serial number | ||
| 51 | Uptime | s | |
| 52 | Uptime total | s | |
| 53 | Model | ||
| 54 | Version |
Notes
[OBSOLETE] ** There is a newer version of this driver ** Three phase electric energy meter. 120-600VAC L-N. External CTs. Modbus 'A-' = D0. For DC powered installations: Provided 0VDC (common) to both the "-" and the C terminals on the WattNode