Airmaster SCCM
Manufacturer: Airmaster
Product: Airmaster
Model: SCCM / FORM
Class: MODBUS
Updated: 2025-01-17
[ CLICK HERE FOR MORE INFORMATION ]
Registers
# | Name | Unit | Description |
---|---|---|---|
1 | Compressor Temperature | °C | |
2 | Line Pressure | bar | |
3 | Sump Pressure | bar | |
4 | Diff pressure | bar | |
5 | Running Hours | h | |
6 | On Load Hours | h | |
7 | Off Load Hours | h | |
8 | Standby Hours | h | |
9 | Hrs Till Oil Filter Service | h | |
10 | Hrs Till Air Filter Service | h | |
11 | Hrs Till Drive Service | h | |
12 | Hrs Till Separator Service | h | |
13 | Hrs Till Oil Change | h | |
14 | Running Period | ||
15 | Unload Period | ||
16 | Load Period | ||
17 | Standby Period | ||
18 | Compressor State | . | |
117 | Compressor Status Flags | . | |
19 | ActiveAlarmA | . | |
20 | ActiveAlarmB | . | |
21 | ActiveAlarmC | . | |
22 | ActiveFaultA | . | |
23 | ActiveFaultB | . | |
24 | ActiveFaultC | . | |
25 | ActiveFaultD | . | |
26 | Active Inhibit | . | |
27 | Motor current | A | |
28 | Main Motor Power | kW | |
29 | Fan Motor Current | A | |
30 | Fan Motor Power | kW | |
31 | Line Voltage | V | |
32 | Package Power | kW | |
33 | Dryer 1 Dew point sensor | °C | |
34 | Dryer 2 Dew Point sensor | °C | |
35 | Digital Inputs | . | |
36 | Relay Ouputs | . | |
37 | Digital Inputs Expansion | . | |
38 | Relay Ouputs Expansion | . | |
39 | Digital inputs XPM | . | |
40 | Relay outputs XPM | . | |
41 | Load pressure Setpoint | bar | |
42 | Unload pressure Setpoint | bar | |
43 | Target Pressure Setpoint | bar | |
44 | Modulation pressure Setpoint | bar | |
45 | Modulation mode | . | |
46 | Star Delta Time | s | |
47 | Load Delay Time | s | |
48 | Standby Run On Time | s | |
49 | Reload Delay Time | s | |
50 | Stop Run On Time | s | |
51 | Blow Down Time | s | |
52 | Actual Unload Pressure | bar | |
53 | Actual Load Pressure | bar | |
54 | Actual Target Pressure | bar | |
55 | Control Mode | . | |
56 | Control for Motor Starts | . | |
57 | No. Motor Starts per hour Limit | N | |
58 | Fan Temp High | °C | |
59 | Fan Temp Low | °C | |
60 | SelectededStartEnable | . | |
61 | SelectedLoadEnable | . | |
62 | Seqeuncing control command | . | |
63 | Sequencing change comand | . | |
64 | Isc Xpm Pressure | bar | |
65 | VSD speed % | % | |
66 | VSD error (VSD) | . | |
67 | VSD Alarm (VSD) | . | |
68 | VSD speed reference (VSD) | Hz | |
69 | VSD output voltage (VSD) | V | |
70 | VSD output current (VSD) | A | |
71 | VSD output power (VSD) | kW | |
72 | VSD Bus Voltage (VSD | V | |
73 | VSD Output Current | A | |
74 | VSD Target Speed Reference | Hz | |
75 | VSD Max Speed | Hz | |
76 | VSD Min Speed | Hz | |
77 | VSD Optimal Speed | Hz | |
78 | VSD Unload Speed | Hz | |
79 | VSD Target Pressure | bar | |
80 | VSD P Factor | . | |
81 | VSD I Factor | . | |
82 | VSD D Factor | . | |
83 | Vsd Preformace Derating | . | |
84 | GetVsdMaxRampRate | . | |
85 | VSD control mode | . | |
86 | F1 | . | |
87 | F2 | . | |
88 | F3 | . | |
89 | RTC | . | |
90 | Preset Oil Filter Service Hours | h | |
91 | Preset Air Filter Service Hours | h | |
92 | Preset Drive Service Hours | h | |
93 | Preset Separator Service Hours | h | |
94 | Preset Till Oil Change Hours | h | |
95 | CT1 A Current | mA | |
96 | CT1 B Current | mA | |
97 | CT1 C Current | mA | |
98 | CT2 A Current | mA | |
99 | Main motor Power Factor | pf | |
100 | Input Voltage of Controller | V | |
101 | Motor Distortion Factor | . | |
102 | Fan Distortion Factor | . | |
103 | Motor Phase Deviation Voltage Max | V | |
104 | Motor Phase Deviation Voltage Min | V | |
105 | Sump Pressure Sensor (mA) | mA | |
106 | Line Pressure Sensor (mA) | mA | |
107 | Motor starts | N | |
108 | Load percentage | % | |
109 | Hours till next service | h | |
110 | Service Hours 1 | h | |
111 | Service Hours 7 | h | |
112 | Service Hours 8 | h | |
113 | Service Hours Preset1 | h | |
114 | Service Hours Preset7 | h | |
115 | Service Hours Preset8 | h | |
116 | GetTemperature | °C |
Notes
Compressor controller Connect: ezeio D0 -> X02 C2-L2 ezeio D1 -> X02 C2-L1 ezeio 0V -> X02 C2-SC