Modbus Injector
Manufacturer: OceanVision
Product:
Model: IS-MOD-0200
Class: MODBUS
Updated: 2023-11-13
[ CLICK HERE FOR MORE INFORMATION ]
Registers
| # | Name | Unit | Description |
|---|---|---|---|
| 1 | Main power voltage | V | |
| 2 | Main power current | A | |
| 3 | Port 1 Voltage | V | |
| 4 | Port 2 Voltage | V | |
| 5 | Port 3 Voltage | V | |
| 6 | Port 4 Voltage | V | |
| 7 | Battery Voltage | V | |
| 8 | Reference Voltage | mV | |
| 9 | Uptime | s | |
| 10 | Error time | s | |
| 11 | Current limit setting | mA | |
| 12 | Over current reset |
Notes
The IS-MOD-0200 is designed to provide a safe, monitored point to power your MODBUS(RTU) 24VDC network. The module can be powered using a 24-48VDC power supply, noting that for longer networks it is recommended to use 48VDC in conjunction with i-Submerge Junction Boxes as they are fitted with 24VDC power regulation to provide each of the 4 MODBUS device ports a clean stable voltage at 24VDC. An embedded backup battery (Protected 18650 - LiFePO4 cell) is also fitted and will keep the MODBUS device alive to enable the network monitoring device to raise the alarm if the power system fails. Connect: Upstream D- to ezeio D0 Upstream D+ to ezeio D1 Upstream GND to ezeio gnd