Controls Inc Panel (D) Safety
Manufacturer: Controls Inc
Product:
Model:
Class: MODBUS
Updated: 2023-11-13
Registers
| # | Name | Unit | Description |
|---|---|---|---|
| 1 | 11005 - Throttle Type | Throttle type | Selection |
| 2 | 11006 - Auto Throttle F2 | Basic | Selection |
| 3 | 11010 - Cooperative TSC | TSC | Selection |
| 4 | 11020 - TSC Min Speed | RPM | Range |
| 5 | 11021 - TSC Max Speed | RPM | Range |
| 6 | 11047 - Speed Limit | RPM | Range |
| 7 | 11048 - Torque Derate Limit | % | Range |
| 8 | 13021 - Fuel Level Check | Selection | |
| 9 | 13022 - Low Fuel Prealarm @ | % | Range |
| 10 | 13023 - Low Fuel Alarm @ | % | Range |
| 11 | 13024 - Fuel Alarm Delay | mmss | Time |
| 12 | 13025 - Fuel Level Alarm Action | Fault actions | Selection |
| 13 | 13030 - Oil Pressure Check | Selection | |
| 14 | 13031 - Low Oil Pressure Prealarm @ | psi | Range |
| 15 | 13032 - Low Oil Pressure Alarm @ | psi | Range |
| 16 | 13033 - Oil Pressure Alarm Delay | mmss | Time |
| 17 | 13034 - Oil Pressure Alarm Action | Fault actions | Selection |
| 18 | 13035 - Oil Pressure Out of Range Action | Fault actions | Selection |
| 19 | 13036 - Oil Pressure Out of Range Delay | mmss | Time |
| 20 | 13040 - Coolant Temperature Check | Selection | |
| 21 | 13043 - Hi Coolant Temperature Prealarm @ | F | Range |
| 22 | 13044 - Hi Coolant Temperature Alarm @ | F | Range |
| 23 | 13045 - Coolant Temperature Alarm Delay | mmss | Time |
| 24 | 13046 - Coolant Temperature Alarm Action | Fault actions | Selection |
| 25 | 13047 - Coolant Temp Out of Range Action | Fault actions | Selection |
| 26 | 13048 - Cool Temp Open (Out of Range) Delay | mmss | Time |
| 27 | 13049 - Cool Temp Short (Out of Range) Delay | mmss | Time |
| 28 | 13050 - Battery Voltage Check | Selection | |
| 29 | 13051 - Low Battery Prealarm @ | V | Range |
| 30 | 13052 - High Battery Prealarm @ | V | Range |
| 31 | 13060 - Overspeed Alarm Check | Selection | |
| 32 | 13061 - Overspeed Alarm @ | RPM | Range |
| 33 | 13062 - Overspeed Alarm Delay | mmss | Time |
| 34 | 13080 - Alarm Action Speed Limit | RPM | Range |
| 35 | 13082 - Alarm Action Torque Derate Limit | % | Range |
| 36 | 13085 - Engine Stall Alarm | Basic | Selection |
| 37 | 13090 - Derate Type | Fault actions | Selection |
| 38 | 13091 - Shutdown Delay | mmss | Time |
| 39 | 13510 - Inlet Pressure Check | Selection | |
| 40 | 13520 - Hi Inlet Vacuum Prealarm @ | Hg | Range |
| 41 | 13530 - Hi Inlet Vacuum Alarm @ | Hg | Range |
| 42 | 13540 - Hi Inlet Pressure Prealarm @ | psi | Range |
| 43 | 13550 - Hi Inlet Pressure Alarm @ | psi | Range |
| 44 | 13555 - Inlet Pressure Alarm Action | Fault actions | Selection |
| 45 | 13560 - Inlet Pressure Alarm Delay | mmss | Time |
| 46 | 13570 - Inlet Pressure Hysteresis | psi | Range |
| 47 | 13580 - Outlet Pressure Check | Selection | |
| 48 | 13590 - Low Outlet Pressure Prealarm @ | psi | Range |
| 49 | 13600 - Low Outlet Pressure Alarm @ | psi | Range |
| 50 | 13610 - Hi Outlet Pressure Prealarm @ | psi | Range |
| 51 | 13620 - Hi Outlet Pressure Alarm @ | psi | Range |
| 52 | 13625 - Outlet Pressure Alarm Action | Fault actions | Selection |
| 53 | 13630 - Outlet Pressure Alarm Delay | mmss | Time |
| 54 | 13640 - Outlet Pressure Hysteresis | psi | Range |
| 55 | 13650 - Flow Rate Check | Selection | |
| 56 | 13660 - Low Flow Rate Prealarm @ | psi | Range |
| 57 | 13670 - Low Flow Rate Alarm @ | gpm | Range |
| 58 | 13680 - Hi Flow Rate Prealarm @ | gpm | Range |
| 59 | 13690 - Hi Flow Rate Alarm @ | gpm | Range |
| 60 | 13700 - Flow Rate Alarm Delay | mmss | Time |
| 61 | 13710 - Flow Rate Hysteresis | gpm | Range |
| 62 | 13720 - Flow Rate Alarm Action | Fault actions | Selection |
| 63 | 13780 - Pump Temperature Check | Selection | |
| 64 | 13783 - Low Pump Temperature Prealarm @ | F | Range |
| 65 | 13786 - Low Pump Temperature Alarm @ | F | Range |
| 66 | 13789 - Hi Pump Temperature Prealarm @ | F | Range |
| 67 | 13792 - Hi Pump Temperature Alarm @ | F | Range |
| 68 | 13795 - Pump Temperature Alarm Action | Fault actions | Selection |
| 69 | 13798 - Pump Temperature Alarm Delay | mmss | Time |
| 70 | 13801 - Pump Temperature Hysteresis | F | Range |
| 71 | 13810 - Pressure Check | Selection | |
| 72 | 13820 - Low Pressure Prealarm @ | psi | Range |
| 73 | 13830 - Low Pressure Alarm @ | psi | Range |
| 74 | 13840 - Hi Pressure Prealarm @ | psi | Range |
| 75 | 13850 - Hi Pressure Alarm @ | psi | Range |
| 76 | 13855 - Pressure Alarm Action | Fault actions | Selection |
| 77 | 13860 - Pressure Alarm Delay | mmss | Time |
| 78 | 13870 - Pressure Hysteresis | psi | Range |
| 79 | 13910 - Level Check | Selection | |
| 80 | 13920 - Low Level Prealarm @ | Ft | Range |
| 81 | 13930 - Low Level Alarm @ | Ft | Range |
| 82 | 13940 - Hi Level Prealarm @ | Ft | Range |
| 83 | 13950 - Hi Level Alarm @ | Ft | Range |
| 84 | 13955 - Level Alarm Action | Fault actions | Selection |
| 85 | 13960 - Level Alarm Delay | mmss | Time |
| 86 | 13970 - Level Hysteresis | Ft | Range |
| 87 | 19010 - Engine Source Address | Value | Range |
| 88 | 19015 - TSC1 Source Address | Value | Range |
| 89 | 19020 - General Source Address | Value | Range |
| 90 | 19021 - Regeneration Switch Source Address | Value | Range |
| 91 | 19023 - Blocked Source Address | Value | Range |
| 92 | 21005 - Auto Start Delay | mmss | Time |
| 93 | 21010 - Crank Cycles | Crank cycles | Range |
| 94 | 21011 - Crank Hold Delay | s | Range |
| 95 | 21020 - Preheat Time | mmss | Time |
| 96 | 21021 - Crank Time | mmss | Time |
| 97 | 21022 - Rest Time | mmss | Time |
| 98 | 21030 - Warmup Speed | RPM | Range |
| 99 | 21031 - Warmup Time | mmss | Time |
| 100 | 21034 - Prime Define (Prime Criteria) | Prime define | Selection |
| 101 | 21035 - Primed @ (Prime Criteria) | s | Range |
| 102 | 21036 - Primed Delay (Prime Criteria) | mmss | Time |
| 103 | 21040 - Prime Speed | RPM | Range |
| 104 | 21041 - Prime Time | mmss | Time |
| 105 | 21050 - Cooldown Speed | RPM | Range |
| 106 | 21051 - Cooldown Time | mmss | Time |
| 107 | 21065 - Rotate Check Delay | mmss | Time |
| 108 | 21066 - Rotate Minimum Speed | RPM | Range |
| 109 | 21070 - Float Logic | Float logic | Selection |
| 110 | 21072 - Wait to Start | Basic | Selection |
| 111 | 21073 - Autostart Off Display Selection | Display | Selection |
| 112 | 21076 - Reengage Logic | Reengage | Selection |
| 113 | 21077 - Transducer Reengage @ | Reengage | Selection |
| 114 | 21078 - Transducer Custom Threshold | Value | Range |
| 115 | 25001 - Start/Stop Transducer | Transducer | Selection |
| 116 | 25002 - Throttle Transducer | Transducer | Selection |
| 117 | 25003 - Start/Stop Input | Start/Stop | Selection |
| 118 | 25013 - On Level | Value | Range |
| 119 | 25014 - Off Level | Value | Range |
| 120 | 25015 - Throttle Mode | Throttle mode | Selection |
| 121 | 25016 - Gain Trim | % | Range |
| 122 | 25022 - Minimum Control Speed | RPM | Range |
| 123 | 25023 - Maximum Control Speed | RPM | Range |
| 124 | 25024 - Minimum Speed @ | Value | Range |
| 125 | 25025 - Maximum Speed @ | Value | Range |
| 126 | 25026 - Maintain | Value | Range |
| 127 | 25027 - Maintain Tolerance | Value | Range |
| 128 | 25031 - Operate Speed | RPM | Range |